Journée Test et Mesure
Calendrier
Organisé par FM Promotion

Journées Test et Mesure »
Dossier d’inscription exposant, tarifs et conditions »

Témoignages
Voici quelques extraits des enquêtes réalisées dans le cadre de nos Journées Test & Mesure
[Exposant] Exposant Toulouse 2011 : Une bonne journée, de bons visiteurs


[Auditeur] Bonne mise au point du vocabulaire à utiliser pour la maintenance.


[Auditeur] Bonne explication sur la différence d'un constat de vérification et un certificat d'étalonnage (conférence maintenance)


Tous les témoignages »

Bilan des Journées Test & Mesure »

Agilent Technologies Introduces Wide-Bandwidth Oscilloscope for Faster, More Accurate Characterisation of High-Speed Digital Designs

Communiqué de presse de AGILENT TECHNOLOGIES RSS

Agilent Technologies Inc. (NYSE: A) today expanded its digital communications analyser (DCA) portfolio with the introduction of the 86100D DCA-X wide-bandwidth oscilloscope. The DCA-X provides engineers with the tools needed to characterise their high-speed digital designs easily and accurately.

The DCA-X mainframe platform will allow engineers to make next-generation measurements that include integrated de-embedding capability. At the same time, the DCA-X is 100 percent backwards compatible with all previous DCA modules and completely code compatible with the 86100C. With future modules, the DCA-X will be able to support up to 16 measurement channels. Higher channel counts will enable electrical and optical engineers to test their parallel designs efficiently, and it offers higher throughput for manufacturing.

The high analog bandwidth, low noise, and low jitter measurements offered by the DCA helps engineers see the true performance of their designs on signals from 50 Mb/s to more than 40 Gb/s. The modular DCA platform can be configured for optical, electrical, TDR/TDT, and S-parameter measurement capability. The 86100D DCA-X improves upon the accuracy and ease-of-use of the 86100C DCA-J by offering:

 o         integrated de-embedding and embedding capability (using the 86100D-SIM InfiniiSim-DCA license);

o         usability enhancements, including:

-       graphical signal processing;

-       dual user interfaces (FlexDCA -- a new customisable vector-based user interface for scope, eye and jitter measurements -- and DCA-J, the “classic” user interface);

-       up to 64 simultaneous measurements; and

-       new measurements, including data-dependent pulse-width shrinkage (DDPWS), uncorrelated jitter (UJ), pre- and de-emphasis measurements and more;

 

o         hardware enhancements, including:

-       vertical gain and offset controls for all channels and functions;

-       user-defined multipurpose button;

-       user-defined analog control knob;

-       faster CPU; and

-       support for up to 16 measurement channels.

As data rates increase, fixtures and probes play a larger role in degrading waveform fidelity and reducing measurement margins. Engineers are often required to remove these unwanted effects to see the true performance of their devices during verification or compliance testing. Likewise, it is very common to measure a clean transmitter and simulate the signal at the output of a typical channel loss model. The 86100D-SIM InfiniiSim-DCA waveform transformation toolset, a powerful new option for the 86100D, allows engineers to perform both of these tasks quickly and accurately.

“The 86100D’s new user interface and integrated de-embedding capability take measurement accuracy and insight to the next level,” said Jay Alexander, vice president and general manager of Agilent’s oscilloscopes business. “The DCA-X provides engineers with the tools to analyse their designs quickly and accurately, allowing them to get their products to market faster.”

Additional information about Agilent’s 86100D DCA-X is available at www.agilent.com/find/dcax.

AGILENT TECHNOLOGIES
Publié le 21-06-2010

Actualités
Nouveautés

Toutes les nouveautés >>

Communiqués de presse

Votre email:
Mot de passe:


Mot de passe perdu   Devenir adhérent

Fermer